Home > News > Company

The air supply system is composed of air inlet net cover, motor, bellows, wind blade, soft coupler,

By DD    2019-12-09 16:59:18

  A burner is a device for ejecting a mixture of fuel and air in a certain way.Burners are classified into industrial burners, burners, civil burners and special burners according to their types and application fields.Multi-purpose stainless steel or titanium metal corrosion resistant, high temperature resistant materials made.The role of the burner is to atomize the sample through flame combustion.The atomized test solution enters the burner and, under the action of flame temperature and atmosphere, goes through drying, melting, evaporation, dissociation and other processes to produce a large number of ground state atoms and some excited state atoms, ions and molecules.A well-designed burner should have the characteristics of high atomization efficiency, low noise and stable flame, so as to ensure high absorption sensitivity and precision of measurement.Gap burners are commonly used in atomic absorption spectrometry to generate atomic vapor.According to the different types of gas and auxiliary gas, the length and width of the gap of the burner are different. Generally, applicable gas and auxiliary gas are marked on the burner.

  Pressure conversion

  1 bar is 10^5 Pa.

  1 dyn/cm2 =0.1 Pa

  Torr =133.322 Pa

  1 mmHg (mmHg) =133.322 Pa

  1 mm water column (mmH2O) =9.80665 Pa

  Engineering atmospheric pressure =98.0665 kPa

  KPa =0.145 psi =0.0102 kg force/square centimeter (KGF /c㎡) =0.0098 atmospheric pressure (ATM)

  1 psi =6.895 kPa =0.0703 kPa =0.0689 bar =0.068 atmosphere

  1 physical atmospheric pressure (ATM) =101.325 kPa =14.696 psi =1.0333 bar 1m³(gaseous) liquefied gas =2.3kg (liquid) liquefied gas

  The proportion of common

  0.81 kg/m&sup 3 gas;2.08 kg/m&sup 3 liquefied petroleum gas;City gas 0.58kg/m³Air is 1.24 kg/m&sup 3;

  Common volume: 1 gallon (gal) =3.785 liters (1)

  Conversion of heat transfer coefficient

  Hour (kcal/ SQM. H) =1.16279 watts/SQM (w/ SQM)

  1 kcal/(m.. ℃) [1 kcal/(m.h. ℃)) = 1.16279 w/(m. Kelvin) w/(m2. K)

  1 British thermal unit /(ft. 2. H.℉) [Btu/(ft2.h.℉)] =5.67826 w/ (m. Kelvin) [(w/ m2.k)]

  1 m2 h.℃/kcal (m2.h.℃/kcal) =0.86000 m2. Kelvin/watt (m2.k /W)

  1 kcal (m.. ℃) (kcal/(m.h. ℃)) = 1.16279 W/(m. Kelvin) W/(m.K)

  1 btu/(feet.. ℉) But/(ft. H. ℉) = 1.7303 W/(m. Kelvin) W/(m.K)

  The air supply system is an important component of the combustion system. The evenness, stability and width of the air volume directly affect the combustion effect and adjusting width.

  The air supply system is composed of air inlet net cover, motor, bellows, wind blade, soft coupler, air inlet muffler (alternative), full cover muffler (alternative) and avoidance support (alternative).

  Steering oil 16 - way composition, available.

  Five-low technology

  Low –CO technology

  Low-NOx technology

  Low O2 technology

  Low noise technology

  Low power consumption technology

  After decades of development, EBICO is beginning to enter a critical period of second entrepreneurship.In the face of the changing market, tide business sea, only firm faith, never give up, forge ahead, constantly beyond, can stand the tide.In the future, we will continue to adhere to the safety, energy saving and environmental protection features of EBICO burner, and build EBICO into a value-added brand that leads the market, exceeds the budget and contributes to the society.

  In terms of comprehensive energy saving, the equipment belongs to the basic hardware of energy saving, but more importantly, it is the human factor. A good management team can control every link with good people, calculate every energy saving factor carefully in the operation, and constantly summarize and improve the management and control level of the team. This is software.And a company attaches great importance to the energy-saving management operation, not only attaches importance to the construction of hardware, attach more importance to the construction of the software, they generally supporting more advanced computer control system, using the global advanced instruments have been supervised, maximize the gain actual operational data, through the computer system constantly improve, constantly upgrade technology, artificial intelligence will be the face of management thinking into a computer program, using new technology to the automatic control of each node, reduce the human error, omission, precise control of boiler system always run in high efficiency and energy saving state, so,A comprehensive, reasonable and advanced computer control system is the best assistant tool for human management.

  Energy saving is a comprehensive project, each node should be controlled, which requires the enterprise to invest a lot of manpower and material resources. The enterprise will constantly improve its management level, and at the same time, it will continue to reap the results of energy saving and consumption reduction, and create better economic benefits.