Home > News > Special

EBICO EBS... series burner is the fourth generation of cpmpact type and electronic proportional cont

By Mr.D    2019-12-02 15:29:03

  Basic knowledge of combustion engine maintenance

  Basic knowledge of burner maintenance:

  1. Keep boiler furnace clean and ensure air circulation in boiler room.When disassembling the burner, the inspection switch should be cut off first.

  2. When the door is locked tightly, the door shall be unshaken and secure;

  3. It is prohibited to burn paper and garbage with the boiler without special declaration;

  4. The gas inlet pressure shall not exceed the maximum allowable pressure of the valve set indicated on the burner nameplate;

  5. Keep the surroundings of the burner clean, so as not to absorb debris into the burner.

  When the combustion engine is started, it must be guaranteed that:

  1. The check switch is on, check the continuous phase;

  2. The valves on the air supply pipeline and the heating system pipeline are open;

  3. The gas pressure is within the pressure range required by the burner;

  4. The regulating plate in the boiler flue must be open (if installed);

  If the burner does not start:

  1. Check whether the valve on the air supply pipe has been opened;

  2. Close the start button and check the setting position of the thermostat, but do not adjust the inside of the thermostat;Check if the fuse is blown.

  Combustion engine does not burn after ignition:

  1. Master the starting condition of the combustion engine, but it is absolutely not allowed to start the combustion engine forcibly;

  2. Do not reignite the burner before the residual gas in the boiler is exhausted;

  3. If the burner has been unable to ignite, professional personnel should be asked to solve.

  During the shutdown of the burner in summer:

  1. Cut off the main inspection and the valve on the natural gas pipeline, if the combustion engine should be repaired in a short time.

  2. Note that the newly installed chimney must be checked whether it is firm when the burner is working, and no vibration or other abnormalities shall occur;

  3. Whether the newly used ignition device can ignite the gas;

  4. If the ignition failure of the combustion engine requires restart, it must wait for about 10 minutes or so, until the residual gas in the furnace dissipates before restart the combustion.Multiple ignition is strictly prohibited.

  5. When the boiler is started and ignited, it is strictly prohibited for all personnel to stay in the front and back of the boiler.

  EBICO EBS... series burner is the fourth generation of cpmpact type and electronic proportional control digital burner researched and development specially for asphalt mixing plant equipment. This burner is designed according to the three major ideas of European products on safety, environmental protection and saving energy, as well as special environment and fuel requirements of China market. It is a new generation of advanced intelligent electronic proportional control machine which is launched to the market after being approved by lots of test and qualified data. This model is scientific and rational in design, compact in size, complete in structure and low in failure rate. Through the application of many new technologies, it can save 5%~12% fuel and at most about 40% electrical energy; it is an ideal product suitable for both fixed asphalt mixing plant and mobile asphalt mixing plant.

  Product features

  Large adjustment ratio: 1:10, advanced electronic computing proportional mode, steady start up, high temperature control accuracy.

  The machine comes with integral compact structure; for the convenience of installation and maintenance, mobile wheel hub device is used

  integrally; oil (gas) supply line and control circuit are arranged compactly and ensures systematic connection; it is novel in design and good-

  looking.

  The fuel oil burner supplies oil at low pressure, air (steam) atomizing and can use poor oil.

  Fuel and combustion oxygen are computed and supplied separately, and the ratio is computed respectively by PLC, so as to ensure complete

  combustion and increase efficiency by 2%.

  The fan applies frequency converting control, so its annual power consumption reduces 30%-40%; featured in high anti-pressure capacity and

  strong adaptation, it can control flame easily.

  The gas burner applies gas ring atomizing and ensures low NOx emission.

  Its safety, energy-saving and environmental protection performance meet European standards.

  Its elements are protected by protective measures, level of protection: IP55; that of master device reaches IP56-IP67. It improves safety and

  eliminates potential failure.

  Applicable fuel: gas, light oil, oil mixture, heavy/residual oil, pulverized coal, oil/gas dual purpose, oil/gas/coal multipurpose, etc.

  This series of burner is applicable for model 500-6000 asphalt mixing plant.

  Intelligent

  Intelligent program controller, digital manipulator, electronic load regulator, frequency regulator(optional),the supported external communication Modbus485 and Profibus-DP can upload controlled data, realize network communication and remote communication, and form accurate and intelligent central control of EBICO.

4.png

  Enough about how to solve the trouble of burner

  EBICO burner products through the investigation, design, testing, finished products, certification, feedback, innovation, guidance eight steps, the safety, energy saving, environmental protection of EBICO series products deductive incisively and vividly, this kind of demanding requirements we are still continuing...